BCH SeriesRugged, Universal or 115/230Vac input, Conduction/convection Cooled | ||||||
Model Name | Output Power (Maximum) | Output Voltage (Maximum) | No. of outputs | Input Voltages | Package/Dimensions (W x H x D) Includes connectors, flanges, screws & fans | Features |
BCH 100 | 100W | 48V | 1 | Universal | F1: 114 x 51 x 201 mm 4.5" x 2" x 7.9" | LBD, Charger Fail Alarm Conduction/convection cooled |
BCH 150 (BCH 1663) | 150W | 48V | 1 | Universal | F2: 114 x 58 x 256 mm 4.5" x 2.3" x 10.1" | LBD, Charger Fail Alarm Conduction/convection cooled |
BCH 152 | 150W | 48V | 1 | 115/230Vac | F2: 114 x 58 x 256 mm 4.5" x 2.3" x 10.1" | Low Battery Disconnect, Low Battery Alarm, Charger Fail Alarm Form C Conduction/convection cooled |
BCH 300 | 300W | 125V | 1 | 115/230Vac | F3: 132 x 64 x 300 mm 5.2" x 2.5" x 11.8" | Charger Fail Alarm Form C Conduction/convection cooled |
BCH 302 | 300W | 125V | 1 | 115/230Vac | F4: 130 x 64 x 353 mm 5.1" x 2.5" x 13.9 | Low Battery Disconnect, Low Battery Alarm, Charger Fail Alarm Form C Conduction/convection cooled |
BCH 300 - 500-PEL | 300 or 500W | 400V | 1 | 115/230Vac | 430 x 341 x 244 mm 17" x 13.5 x 9.7" Pelican Top-loader Case #1430 | Charger Fail Alarm Form C option, BTC option Portable. Waterproof case. Cooling by natural convection |
BCH MO1 | 300, 500 or 750W | 138V | 1 | 115/230Vac | ( H x W x D) 4U (6.97") x 19" x 7" | Configurable charger system Cooling by conduction/ convection or built-in fans |
BCH 65-3U/19M | 300W | 125V 120A | 1 | 115/230Vac | ( H x W x D) 3U x 19" x 3" | Output fail alarm, front panel adjustment, output voltage & current meters, input switch |
BCH 500 | 500W | 125V | 1 | 115/230Vac | F4: 130 x 64 x 353 mm 5.1" x 2.5" x 13.9" | Charger Fail Alarm Form C Conduction/convection cooled |
BCH 502 | 500W | 125V | 1 | 115/230Vac | F5: 130 x 64 x 432 mm 5.1" x 2.5" x 17” | Charger/AC fail alarm, Low Battery Alarm, Low Battery Disconnect,Optional BTC Conduction/convection cooled |
BCH 2K5-120NP-EQ | 2500W | 135Vdc | 1 | 240Vac 190-264Vac range | 610 x 203 x 610 mm 24” x 8” x 24” | Cooling by convection Wall-mounted case, louvers |
ABBREVIATIONS:LBD: Low Battery Disconnect; BTC: Battery Temperature Compensation; LBA: Low Battery Alarm | ||||||
BCP SeriesRugged, PFC-input, Conduction/convection or Fan Cooled | ||||||
Model Name | Output Power (Maximum) | Output Voltage (Maximum) | No. of outputs | Input Voltages | Package/Dimensions (W x H x D) Includes connectors, flanges, screws & fans | Features |
BCP 150 | 150W | 48V | 1 | 90 - 264Vac PFC | F2L: 114 x 57 x 310 mm 4.5"x 2.3" x 12.2" | Charger fail F/O or F/C |
BCP 152 | 150W | 48V | 1 | 90 - 264Vac PFC | F2L: 114 x 57 x 310 mm 4.5"x 2.3" x 12.2" | Charger/AC fail alarm F/C Low Battery Alarm F/C |
BCP 1K - 27CB | 1000W | 24V | 1 | 115Vac PFC 100V-132Vac range | 140 x 165 x 356 mm 5.5” x 6.5” x 14” | Charger for Vehicles in Cold Climates |
BCP 1K5-PEL | 1500W | Any requested voltage in the 20 - 400V range | 1 | 180Vac to 264Vac PFC (EN61000-3-2)e | 502 x 188 x 400 mm 19.8” x 7.5” x 15.8” Pelican Case #1520 | Portable for field applications. Pelican splash-proof case. Cooling by built-in fans |
BCP 2K-E-600 | 2000W | 600V | 1 | 90 - 264Vac PFC or 190 - 264Vac PFC | 3U3: 187 x 132 x 407 mm 7.4 x 5.2 x 16" | - |
ABBREVIATIONS: LBD: Low Battery Disconnect; BTC: Battery Temperature Compensation; LBA: Low Battery Alarm | ||||||
UPS 12-SeriesRugged, Universal input, DC-output UPS Systems, Conduction/convection cooled | ||||||
Model Name | Output Power (Maximum) | Output Voltage (Maximum) | No. of outputs | Input Voltages | Package/Dimensions | Features |
UPS 12-7AH | 50W | 13.6V | 1 | Universal | 157.5 x 71.1 x 254 mm 6.2" x 2.8" x 10" | Built-in 7AH battery. Compact design. |
UPS 12-14AH | 150W | 13.8V | 1 | Universal | 140 x 178 x 254 mm 5.5" x 7" x 10" | Built-in 7AH battery. Compact design. |