Battery Chargers/UPS | BCH | BCP | UPS-12 Series

BCH Series


Rugged, Universal or 115/230Vac input, Conduction/convection Cooled
Model Name Output Power
(Maximum)
Output Voltage
(Maximum)
No. of outputs Input
Voltages
Package/Dimensions
(W x H x D)
Includes connectors, flanges, screws & fans
Features
BCH 100 100W 48V 1 Universal F1: 114 x 51 x 201 mm
4.5" x 2" x 7.9"
LBD, Charger Fail Alarm
Conduction/convection cooled
BCH 150
(BCH 1663)
150W 48V 1 Universal F2: 114 x 58 x 256 mm
4.5" x 2.3" x 10.1"
LBD, Charger Fail Alarm
Conduction/convection cooled
BCH 152 150W 48V 1 115/230Vac
F2: 114 x 58 x 256 mm
4.5" x 2.3" x 10.1"
Low Battery Disconnect,
Low Battery Alarm,
Charger Fail Alarm Form C
Conduction/convection cooled
BCH 300 300W 125V 1 115/230Vac
F3: 132 x 64 x 300 mm
5.2" x 2.5" x 11.8"
Charger Fail Alarm Form C
Conduction/convection cooled
BCH 302 300W 125V 1 115/230Vac
F4: 130 x 64 x 353 mm
5.1" x 2.5" x 13.9
Low Battery Disconnect,
Low Battery Alarm,
Charger Fail Alarm Form C
Conduction/convection cooled
BCH 300 - 500-PEL 300 or 500W 400V 1 115/230Vac
430 x 341 x 244 mm
17" x 13.5 x 9.7"
Pelican Top-loader
Case #1430
Charger Fail Alarm Form C option, BTC option
Portable. Waterproof case.
Cooling by natural convection
BCH MO1 300, 500 or 750W 138V 1 115/230Vac ( H x W x D)
4U (6.97") x 19" x 7"
Configurable charger system
Cooling by conduction/ convection or built-in fans
BCH 65-3U/19M 300W 125V
120A
1 115/230Vac ( H x W x D)
3U x 19" x 3"
Output fail alarm, front panel adjustment, output voltage & current meters, input switch
BCH 500 500W 125V 1 115/230Vac
F4: 130 x 64 x 353 mm
5.1" x 2.5" x 13.9"
Charger Fail Alarm Form C
Conduction/convection cooled
BCH 502 500W 125V 1 115/230Vac
F5: 130 x 64 x 432 mm
5.1" x 2.5" x 17”
Charger/AC fail alarm, Low Battery Alarm, Low Battery Disconnect,Optional BTC
Conduction/convection cooled
BCH 2K5-120NP-EQ 2500W 135Vdc 1 240Vac
190-264Vac range
610 x 203 x 610 mm
24” x 8” x 24”
Cooling by convection
Wall-mounted case, louvers
ABBREVIATIONS:
LBD: Low Battery Disconnect; BTC: Battery Temperature Compensation; LBA: Low Battery Alarm

BCP Series


Rugged, PFC-input, Conduction/convection or Fan Cooled
Model Name Output Power
(Maximum)
Output Voltage
(Maximum)
No. of outputs Input
Voltages
Package/Dimensions
(W x H x D)
Includes connectors, flanges, screws & fans
Features
BCP 150 150W 48V 1 90 - 264Vac PFC F2L: 114 x 57 x 310 mm
4.5"x 2.3" x 12.2"
Charger fail F/O or F/C
BCP 152 150W 48V 1 90 - 264Vac PFC F2L: 114 x 57 x 310 mm
4.5"x 2.3" x 12.2"
Charger/AC fail alarm F/C
Low Battery Alarm F/C
BCP 1K - 27CB 1000W 24V 1 115Vac PFC
100V-132Vac range
140 x 165 x 356 mm
5.5” x 6.5” x 14”
Charger for Vehicles
in Cold Climates
BCP 1K5-PEL 1500W Any requested voltage in the 20 - 400V range 1 180Vac to 264Vac
PFC (EN61000-3-2)e
502 x 188 x 400 mm
19.8” x 7.5” x 15.8”
Pelican Case #1520

Portable for field applications. Pelican splash-proof case. Cooling by built-in fans

BCP 2K-E-600 2000W 600V 1 90 - 264Vac PFC or
190 - 264Vac PFC
3U3: 187 x 132 x 407 mm
7.4 x 5.2 x 16"
-
ABBREVIATIONS:
LBD: Low Battery Disconnect; BTC: Battery Temperature Compensation; LBA: Low Battery Alarm

UPS 12-Series


Rugged, Universal input, DC-output UPS Systems, Conduction/convection cooled
Model Name Output Power
(Maximum)
Output Voltage
(Maximum)
No. of outputs Input
Voltages
Package/Dimensions Features
UPS 12-7AH 50W 13.6V 1 Universal 157.5 x 71.1 x 254 mm
6.2" x 2.8" x 10"
Built-in 7AH battery. Compact design.
UPS 12-14AH 150W 13.8V 1 Universal 140 x 178 x 254 mm
5.5" x 7" x 10"